# Tenoning Jig

Hewn Tool Library · https://hewn.build/tools/tenoning-jig

Corrected: An independent reviewer read this entry and found corrections. They have been applied to the text, and the reviewer re-checked the correction that mattered most for safety and found it done; the others have not been re-checked yet. The list at the end is the record of what changed.

Cite as: "Tenoning Jig." Hewn Tool Library, hewn.build/tools/tenoning-jig. Reviewed 2026-09-19.

---

## Identity

- **What it is, in a sentence.** A guided clamping fixture that holds stock upright, or at a controlled angle where the model supports it, and carries it past a table-saw blade to cut the cheeks of an integral tenon.
- **Two guide families, not one.**
  - **Miter-slot-guided tenoning jig** — the common commercial cast-metal form. Grizzly H7583 and T30491 need "a 3/8" x 3/4" miter T-slot on the left side of the blade," with the slot center 3¾" to 6¾" from the blade (manuals, read). The Delta 34-183 manual: "Place the tenoning jig guide bar (A) Fig. 12 into the left miter slot (D)" (ManualsLib copy, read). Delta's current 34-184 is described by the reviewer as having a universal miter bar for standard 3/8" × 3/4" slots, an angular backstop and micro-adjustment `[manual, relayed]`.
  - **Fence-saddle tenoning jig** — mostly shop-built; it encloses or rides a rigid rip fence. Named examples: Bill White's and Mike Wilkins's shop saddle jigs and Dave Cav's retired homemade fence-riding jig (Sawmill Creek). Its compatibility, stability and anti-lift behavior depend on that fence and that build.
- **Also called:** tenoning fixture, tenon jig, vertical tenoning jig. Commercial examples: Delta No. 1172/34-172, Delta 34-183/34-184, Grizzly H7583/T30491; Strother Purdy's *Fine Woodworking* #175 roundup (Jan/Feb 2005) covered models from Delta, Garrett Wade, General, Jet/Powermatic, Rockler, Shop Fox, Woodcraft, Woodtek and Yorkcraft (synopsis; whether Jet and Powermatic count as one maker or two is not settled from the synopsis).
- **It cuts cheeks, not shoulders.** In the manufacturer procedures read, the jig makes the cheek cuts; shoulder cuts are a separate table-saw operation made after the jig is removed (Delta: the jig is designed to "Perform cheek cuts that precede shoulder cuts").
- **Distinct from — IF/THEN.** IF the device is a floor-standing powered machine with its own feed and cutterheads, THEN it is the [[Tenoning Machine (Single-End/Double-End Tenoner)]], not this jig. IF the device carries stock flat on a sled in the miter slots, THEN it is a [[Crosscut Sled]] or joinery-sled variant. Both this jig and the sled may ride a miter slot; the jig holds stock upright to cut cheeks. IF the workpiece rotates on an axis into a dado blade to make round tenons, THEN it is a rotary tenonizer such as US5,597,023A, not this jig.

## How NOT to use it (the heaviest section)

**not-for**
- IF the joint is a loose/floating tenon, THEN this jig is not the tool (Mike Monroe).
- IF production has outgrown hand-fed cheek cuts, THEN use the [[Tenoning Machine (Single-End/Double-End Tenoner)]].
- IF the jig, saw, blade, riving knife, insert or guard arrangement conflict, THEN do not run it.
- Not for box joints, dados or splines unless that exact model's manual documents the operation with its cutter, guarding, indexing and support.

**dangerous (injures the user)**
- **This operation can expose more blade than an ordinary guarded cut.** The hazards are blade contact, jig-to-blade collision, the jig lifting, binding, offcut breakage and kickback. The controls are the manufacturer's full setup and cut-and-reset sequence in Correct use; stance alone is not a control.
- **Untrained use.** Grizzly: "serious injury hazards to untrained users"; "trained operators only."
- **Lift and kickback.** Feeding fast lets the blade lift the jig (T30491). Missing T-slot washers let the jig come loose during kickback (H7583). Use the riving knife where specified.
- **Jig-to-blade contact.** Keep the side support at least ½" from the blade (Grizzly) and dry-run the travel with power disconnected.
- **Waste and offcuts.** Support the waste with the side backing board; feed completely through; do not reach for, move or clear an offcut until the saw is off, disconnected and the blade stopped. Dean's report of the first cheek offcut "trapped between the saw blade and jig" on the following pass is practitioner evidence of this concern.
- **Hands and body.** Both hands on both handles; never one-handed; body out of line with the blade; never pull back through a running blade; never reach over the blade.
- **Shoulders.** Simultaneous contact with the miter gauge and the rip fence at the blade can trap the workpiece and cause kickback; use a stop block positioned so the workpiece is clear of it during the cut, and a crosscut blade (Grizzly; "a cross-cut saw blade" — another blade can grab the workpiece, per the reviewer's reading of the manual `[manual, relayed]`).
- **Guards.** Restore the blade guard and all saw safety features immediately after removing the jig. In covered US workplaces, OSHA 29 CFR 1910.213(a)(15) requires that "Combs (featherboards) or suitable jigs shall be provided at the workplace for use when a standard guard cannot be used," and 1910.213(r)(4) keeps other woodworking machines subject to "suitable guards ... to reduce to a minimum the hazard due to the point of operation" (read). OSHA governs covered employment, not every home shop, but it supports the same order: guard where possible, suitable jig or barrier where not.
- **Shop-built jigs.** A flexible, lifting or poorly captured jig can rotate the stock or the jig into the blade (see the required properties in Correct use).

**damaging (ruins the tool or the work)**
- **★ Loose or worn guidance causes rocking and out-of-spec cuts.** Dave Cav's homemade fence-riding jig "rock[ed]" and cut a narrow tenon.
- **Coarse adjustment hurts repeatability.** Quinn's comparison of a vintage Delta with a newer commercial jig.
- **Batching from the wrong reference** can repeat a centering error across every piece; test and gauge before batching.
- **Running without the back support board** invites tear-out (Grizzly).

**beginner-trap (looks fine until it isn't)**
- **★ Buying a commercial jig without checking its exact compatibility against the saw.** Check slot profile, required side and slot-center-to-blade range (Grizzly: 3/8" × 3/4" left T-slot, 3¾"–6¾"). England's jig could not reach within 1.5″ of his Jet SuperSaw's blade.
- **Treating stance as the safety plan.** Standing out of line is one control among the setup, clamping, backing, riving-knife, two-hand, feed, power-off and guard steps.
- **Carrying the stop-block rule onto the cheek jig, or the cheek setup onto shoulders.** They are separate operations with different setups and blades.
- **Assuming vintage cast iron is more accurate.** Cav and Quinn both report the opposite for this tool.

**lineage-misuse (treating it like an ancestor, descendant, or a tool from a different trade)**
- **★ Confusing this jig with the industrial [[Tenoning Machine (Single-End/Double-End Tenoner)]].** IF the device is floor-standing and powered with its own feed, THEN it is the machine; guidance does not transfer either way.
- **Assuming every tenoning jig rides the same guide.** Commercial jigs commonly ride the left miter slot; shop-built saddle jigs ride the fence; their checks differ.
- **Confusing this jig with the [[Crosscut Sled]]**, which carries stock flat for crosscuts.

## Correct use

**Genuinely good at:** cutting accurate, repeatable tenon cheeks on a table saw without hand-holding stock upright against the blade, when the exact jig and saw are compatible and set up per their manuals.

**Who should run it.** Trained or closely supervised table-saw operators. Grizzly: "Using the jig with the table saw presents serious injury hazards to untrained users"; the T30491 manual: "trained operators only. untrained operators have a higher risk of being hurt or killed." A beginner should not proceed from this entry alone: get instruction on the exact saw and jig, kickback, guards and riving knife, power disconnection for setup, two-hand control and offcut handling.

**Setup, with the saw disconnected from power** (Grizzly H7583/T30491 values; use your own model's manual):
- Both the saw and jig manuals must permit the configuration. Check the slot profile and side (Grizzly: 3/8" × 3/4" T-slot, left of the blade) and the slot-center-to-blade distance (Grizzly: 3¾"–6¾"). Do not use the jig where the jig, blade, riving knife, insert, guard arrangement or travel path conflict.
- Blade "perpendicular to the table and parallel with the miter slots."
- Guide bar adjusted to slide with no side-to-side play or tilt.
- T-slot retention washers installed.
- Side support at least ½" from the blade at all times (safety-stop screw set).
- Back support board, side support board and base piece installed as the manual requires.
- Riving knife: "ALWAYS use a riving knife that is correctly installed on the table saw when making the tenon cuts" (H7583).
- Blade: the one the jig and saw manuals specify for the cut, with correct diameter, kerf, tooth geometry, sharpness and riving-knife compatibility.
- Workpiece clamped securely; every lock tightened; setup tools cleared.
- **Dry clearance check:** with power still disconnected, move the jig through its full travel and confirm no part of it can contact the blade and the path is unobstructed.

**The cut:**
- Stand out of line with the blade: "Never stand or have any part of your body directly in-line with the cutting path of the saw blade" (H7583).
- "ALWAYS firmly hold both tenoning jig handles when cutting. NEVER hold the jig with one hand" (H7583).
- Feed slowly and completely through: "Do not move jig and workpiece into blade quickly or force of blade will attempt to lift jig up and away from table" (T30491).
- Never pull the jig back through a running blade.
- Stop immediately on binding, rocking, lift or unexpected resistance.

**Between cuts:** turn the saw off and wait for the blade to stop (Grizzly); disconnect power before unclamping, rotating, clearing waste, removing the workpiece or readjusting the jig ("Disconnect the saw from power BEFORE installing or adjusting the jig, saw, or workpiece"). Return the jig, rotate and reclamp the workpiece, and verify alignment before the next cut. Grizzly's sequence: first structural cheek, turn the workpiece 180° for the second, then the third and fourth cosmetic cheek cuts where needed.

**Shoulders are a separate setup.** Remove the jig. Grizzly: "ALWAYS use a cross-cut saw blade when making the tenon shoulder cuts"; set blade height; attach a backing board to the miter gauge; clamp a stop block to the fence "far enough behind blade so that workpiece will not contact stop block during cut" (T30491). The Delta 34-183 manual words it as positioning the stop block "in front of the saw blade" to prevent kickback (ManualsLib copy); either way the rule is the same: the workpiece must be free of the stop block before and during the cut. Never use the rip fence as a simultaneous crosscut guide at the blade. Push the miter gauge slowly through.

**Afterwards:** "Always re-install the blade guard and any other safety features for the table saw when the tenoning jig is removed" (H7583); Delta: "Reinstall the blade guard of the saw immediately after jig use is complete."

**Batching and accuracy.** Dean's method (all front cheeks, reset, all back cheeks) is one production method. Before batching, settle a reference-face and dimensioning plan, prepare stock consistently, make test cuts in representative scrap and check them against the actual mortise or a setup gauge; flipping each piece at one setting or cutting to a gauge can give different results depending on stock thickness variation and tenon centering.

**Fit before first use.** A loose or rocking guide gives inconsistent, unsafe cuts (Dave Cav's account). Commercial jigs: adjust the guide bar to zero play per the manual. Shop-built jigs: see below.

**Shop-built jigs are not a casual low-cost equivalent.** Use one only if it is a proven design compatible with the exact saw and has: rigid, full-length fence engagement (on a rigid, parallel fence) or other positive guidance; anti-lift control; low play; secure clamping and a clamping face square to the table; sufficient blade clearance; two-hand control with handles placed out of the blade path; backing for waste; a complete travel path with stops; and compatibility with the saw's guard and riving knife. Validate it with power disconnected. Otherwise, use a manufacturer-approved jig.

## Matching (the workbench's first read)

- **Does:** clamps a workpiece upright and guides it past a table-saw blade to cut integral-tenon cheeks. Angled cheeks only on models whose support and backstop are designed and documented for them. Box joints, grooves, dados and splines are not category-level capabilities; they need an exact model's documented support.
- **Selection fields, by guide family.**
  - *Miter-slot jig:* slot width/depth/T-profile; required left or right slot; slot-center-to-blade range; guide-bar mounting positions; anti-lift hardware; saw-table clearance; blade/slot alignment; supported saw models.
  - *Fence-saddle jig:* fence cross-section; rigid, parallel fence; full capture; low play; anti-lift behavior; clamping face; support height; travel stops; blade clearance; guard/riving-knife compatibility.
- **Project fields:** workpiece length, width, straightness, moisture, defects, clamping area and center of mass; outfeed clearance; tenon dimensions; shoulder method; blade capacity; integral vs. loose tenon. Tall, long, tapered or irregular stock may need a different fixture or machine even if it fits the clamp.
- **Suits:** integral mortise-and-tenon joinery at small-shop volume — chairs, tables, frame-and-panel doors, casework.
- **Kit-fit — pairs with:** the blade each manual specifies for cheek cuts; a correctly installed riving knife where specified; the required support boards; and, for the separate shoulder step, a miter gauge with backing board, a crosscut blade and a fence stop block.
- **Alternatives:** IF a shop prefers a bandsaw, THEN cheeks can be cut on the bandsaw as an alternate workflow, with its own fence or jig, blade, support and fitting steps, and possibly a different surface and tolerance (Dave Aronson). IF the designer accepts a loose/floating-tenon joint, THEN a router or loose-tenon system replaces the integral tenon; that is a joint redesign with structural, visual, grain and sequencing consequences, not a tool swap (Mike Monroe). IF volume outgrows hand-fed cutting, THEN the [[Tenoning Machine (Single-End/Double-End Tenoner)]] is the step up.
- **Not-for (project-keyed):** IF the jig and saw are not shown compatible by their manuals, THEN do not use it (England/Jones is one failure example). IF the stock is too tall, long or irregular to clamp and travel stably, THEN use another method.
- **Access:** trained or closely supervised table-saw work. A commercial accessory does not lower the consequence of an exposed-blade mistake.
- **Revival:** none; a live, manufactured and shop-built accessory.

## Anatomy

- **Miter-slot-guided commercial jig (Grizzly H7583/T30491 parts, per their manuals and the reviewer's notes):** guide bar in the left T-slot, adjustable for zero side-to-side play or tilt; **T-slot retention washers** on the guide bar, which the manual warns must stay on or the jig can come loose during kickback; slide plate; **side support** with a safety-stop set screw keeping it at least ½" from the blade; **back support**; clamps; micro-adjuster; locks; two operating handles.
- **Wooden support boards (Grizzly):** a **back support board** that prevents tear-out; a **side support board**, "an additional safety barrier between the jig and the saw blade"; and a 3/8" **base piece** clamped to the table to give the workpiece a level surface and reduce binding. Where the manual calls for them, they are required, not accessories.
- **Fence-saddle shop-built jig:** a body that captures or straddles the rip fence, a vertical clamping face, and whatever clamping, anti-lift and handle arrangement the build provides. These vary by builder and must be checked one by one.
- **Adjustment quality varies.** Quinn's comparison: a vintage Delta's "crude left-right" adjustment vs. finer control on newer commercial jigs.
- **[Forge image needs]:** (1) a miter-slot-guided jig on the left slot, stock clamped upright, side and back support boards, the ½" safety-stop clearance and the operator's out-of-line stance marked; (2) a side-by-side of the miter-slot-guided jig and a fence-saddle jig; (3) the separate shoulder-cut setup: jig removed, miter gauge with backing board, fence stop block positioned so the workpiece is clear of it during the cut.

## Variations (living)

| Variant | Guide | Notes | Source |
|---|---|---|---|
| Grizzly H7583 / T30491 | Left 3/8" × 3/4" miter T-slot, slot center 3¾"–6¾" from blade | Riving knife required for cheek cuts; ½" safety stop; backing boards | Grizzly manuals, read |
| Delta 34-183 (2006) / 34-184 (current) | Left miter slot guide bar (34-183, read); universal 3/8" × 3/4" miter bar (34-184 `[manual, relayed]`) | Two handles, slow feed, guard reinstalled after use | ManualsLib copy, read; Delta page returned no specs |
| Delta No. 1172/34-172 (cast iron) | "Guide key" listed; engagement not stated on the page read | ~30 lb; early, well-documented Delta example; crude adjustment per later users | Old Woodworking Machines; Quinn; dated catalogues `[manual, relayed]` |
| Commercial field, mid-2000s | Various | Delta, Garrett Wade, General, Jet/Powermatic, Rockler, Shop Fox, Woodcraft, Woodtek, Yorkcraft | Purdy, *FWW* #175 (synopsis) |
| Fence-saddle shop-built jig | Rip fence | Individual builds reported to work (White) or rock and cut out of spec (Cav); not a validated equivalent | Sawmill Creek |
| Rotary/rocker tenonizer (adjacent, not this tool) | Axis shaft, dado blade | Round tenons | US5,597,023A |
| Tenoning attachment, Hammerling (adjacent) | Base clamped to table; guide parallel to blade; miter-gauge slot | 1957 filing | US2,941,556A |

## Trades (where it appears)

**Core woodworking — table-saw joinery in furniture and cabinetmaking** (frame-and-panel work, chairs, tables, doors). Cited in [[Table Saw]] and [[Track Saw]].

## Lineage

- **Patents.** US5,597,023A ("Table saw tenonizer jig," Michael G. Heintzeman, filed 1995-11-09, priority 1992-12-21, granted 1997-01-28, read in Run 631) is a rotary/rocker device: the workpiece rotates on an axis shaft into a dado blade to cut round tenons. It cites US2,777,485 (Benjamin J. Farrow, 1957, "Means for cutting uniformly spaced tenons"), US5,020,578 and US5,065,802, not read. **US2,941,556A**, "Tenoning attachment for table saws," Franz Hammerling, filed April 10, 1957, published June 21, 1960 (read this pass): "a relatively large base having means for clamping the same to a saw table," a guide member "which can move only parallel to the saw blade," and "an elongated guide slot 86 for receiving a conventional miter gauge." It is adjacent patent evidence; it does not establish descent to the Delta-style vertical jig. No patent confidently matching the Delta-style sliding vertical jig was identified in the searches documented for this entry; that is not a finding of absence. Run 631 did not record its query terms or classifications.
- **The hand-cut mortise-and-tenon joint** is the trade purpose this jig mechanizes one half of.
- **An early, well-documented Delta commercial example: No. 1172/34-172.** A cast-iron jig of "approximately 30 pounds," per a reproduced Delta instruction sheet on Old Woodworking Machines (a collector's reconstruction, not a Delta archive; read), described as "ruggedly designed for safe operation in furniture, sash and cabinet factories" and other shops. The page lists a "guide key" among the parts but does not say how it engages the saw. Dated records the reviewer names: a 1948 Delta catalogue listing No. 1172 as a tenoner with base plate; Delta publication PM-1731, dated 24 February 1950, for Nos. 1170 and 1172; a 1969 Rockwell-Delta catalogue still listing the 1172 tenoning attachment `[manual, relayed]`. Later continuity in the miter-slot-guided form: the 2006 Delta 34-183 manual (read, secondary copy) and the current 34-184 `[manual, relayed]`. **Not established:** that No. 1172 was the first commercial tenoning jig; a worthpoint.com listing's claim of a 1937 Delta catalogue placement is an unconfirmed lead.
- **A mature commercial field by 2005**, per Purdy's *Fine Woodworking* roundup.
- **Contemporary methods** — a bandsaw cheek-cutting workflow; a dado blade run flat with a miter gauge or sliding table; loose/floating-tenon joinery (a different joint system); and the industrial [[Tenoning Machine (Single-End/Double-End Tenoner)]].

## History (Petroski "form follows failure" lens)

**The jig answers a specific limitation: holding stock upright and steady against a spinning blade by hand alone is inaccurate and unsafe.** No dated origin-story article was located. The dated anchors are the Delta 1172 records above and the 2005 Purdy roundup.

## Human Side

*Named practitioners below are quoted from public forum posts gathered in Run 631, at forum-evidence weight. This entry is AI-compiled corpus material, not a craftsperson's testimony; forum practice does not overrule the manufacturers' setup, guarding or operating instructions.*

- **Dean ("dstevick")** — Fine Woodworking forum, Nov 24 2006. His production method with a Delta jig: front cheek on all pieces first, then reset for the back cheek, checking thickness against the mortise with a $35 digital caliper. He reports that cutting the first cheek "causes the first cheek cutoff to be trapped between the saw blade and jig" on the following pass, and stands out of the blade line. This is one practitioner's evidence of an offcut-binding concern, not the complete hazard model (see Dangerous).
- **BarryO** — same thread, 2006. Recommends, "mainly ... for safety," an auxiliary fence block set back about half an inch so stock loses fence contact before the blade. That is the stop-block principle for crosscut shoulder work, not a fixture of the cheek-cutting jig (see Correct use).
- **Prashun Patel and Jim Becker** — Sawmill Creek, 2010, on build vs. buy: Patel built his own, "if it was bad I could always buy one"; Becker sees buying as reasonable for a maker who "struggle[s] for time for furniture projects."
- **Dave Cav** — Sawmill Creek, 2010/2011. Retired a homemade fence-riding jig after it intermittently "rock[ed]" and cut a narrow tenon; switched to a commercial Grizzly jig, "a lot more accurate and easier to use," and prefers it to his father's vintage Delta 1172 because it is "easier to adjust."
- **Peter Quinn** — Sawmill Creek, 2011. Owns a $50 Woodcraft jig and a vintage shop Delta; calls the Delta "a big cranky dinosaur that works better on a shelf than on a saw" (no slop adjustment, crude left-right adjustment) and "actually prefer[s]" the Woodcraft.
- **Mike Monroe** — Sawmill Creek, 2011. Moved to loose/floating tenons, which he says "makes a table saw tenoning jig moot" for his work.
- **Zach England and J. Greg Jones** — Sawmill Creek, 2009. England's commercial jig, installed per its manual, could not get within 1.5″ of the blade on his Jet SuperSaw (whose miter slots he gives as 7″ apart, vs. the 5.5″/4.25″ he expected); Jones corroborates a known SuperSaw incompatibility for a related jig. England's fix, 3/4″ MDF screwed to the jig face, was "workable but annoying."
- **Dave Aronson, Frank Drew, Steve Griffin, Bill White, Mike Wilkins** — Sawmill Creek, 2010/2011. Aronson: "I just use my bandsaw for it"; Drew and Griffin use a dado blade run flat with a miter gauge or sliding table ("Haven't used a tenoning jig since high school shop"); White built a shop saddle jig riding the rip fence and reports it works; Wilkins planned the same. These are reports of individual builds, not validation of shop-built jigs in general (see Correct use).

## Proof of existence

- **Current commercial manuals**: Grizzly H7583 and T30491 (cdn0.grizzly.com, read); Delta 34-183 (2006; ManualsLib copy, read).
- **An early, well-documented Delta product: No. 1172/34-172**, from a reproduced instruction sheet (Old Woodworking Machines, read) and dated Delta records of 1948, 1950 (PM-1731) and 1969 named by the reviewer `[manual, relayed]`. Earliest catalogue date not confirmed; the 1937 claim is an unconfirmed lead.
- **A mature commercial field by 2005**, per Purdy's *Fine Woodworking* #175.
- **Adjacent patents**: US5,597,023A (rotary tenonizer); US2,941,556A (Hammerling tenoning attachment, 1957/1960). No patent confidently matching the Delta-style vertical jig was identified in the searches documented.
- **Museum record**: no relevant record was located in the Smithsonian collections searches documented for this entry (Run 631; query terms not recorded). The Mercer Museum catalogue was not reachable and remains an open gap.

## References

| Title | Author/Source | Kind | Notes |
|---|---|---|---|
| "Table Saw" | this corpus, [[Table Saw]] | corpus cross-reference | citing entry |
| "Track Saw" | this corpus, [[Track Saw]] | corpus cross-reference | citing entry |
| "Crosscut Sled" | this corpus, [[Crosscut Sled]] | corpus cross-reference | sibling accessory |
| "Tenoning Machine (Single-End/Double-End Tenoner)" | this corpus | corpus cross-reference | industrial machine, out of scope |
| Grizzly H7583 Tenoning Jig manual | Grizzly, https://cdn0.grizzly.com/manuals/h7583_m.pdf | manufacturer manual, read 2026-10-16 | slot spec, alignment, washers, ½" stop, boards, riving knife, two hands, feed, power-off, crosscut blade for shoulders, guard |
| Grizzly T30491 Tenoning Jig manual | Grizzly, https://cdn0.grizzly.com/manuals/t30491_m.pdf | manufacturer manual, read 2026-10-16 | trained operators only; lift warning; stop-block placement |
| Delta 34-183 instruction manual (2006) | Delta, secondary copy, https://www.manualslib.com/manual/2868852/Delta-34-183.html | manufacturer manual, secondary-hosted, read 2026-10-16 | left miter slot, two handles, slow feed, full stop, guard, cheek-before-shoulder, stop block |
| Delta 34-184 Universal Tenoning Jig | Delta, https://deltamachinery.com/product/34-184-universal-tenoning-jig/ | manufacturer page `[manual, relayed]` (no specs returned) | universal 3/8" × 3/4" miter bar, angular backstop, micro-adjustment (per the reviewer) |
| 1969 Rockwell-Delta catalogue | pearl-hifi.com scan | catalogue `[manual, relayed]` (fetch refused) | No. 1172 still listed (per the reviewer) |
| 1948 Delta catalogue; Delta PM-1731 (24 Feb 1950) | Delta | catalogue/publication `[manual, relayed]` (not located) | No. 1172 records (per the reviewer) |
| Delta No. 1172/34-172 instruction-sheet reconstruction | Ben Anderson, Old Woodworking Machines, https://www.old-woodworking-machines.com/delta-no-1172-tenoning-jig/ | collector reconstruction, read 2026-10-16 | ~30 lb; factory/shop use; guide key; not a Delta archive |
| Delta 1937 catalogue placement claim | worthpoint.com listing | listing, unverified | lead only |
| US5,597,023A, "Table saw tenonizer jig" | Michael G. Heintzeman, filed 1995, granted 1997 | patent, read (Run 631) | rotary tenonizer, adjacent |
| US2,941,556A, "Tenoning attachment for table saws" | Franz Hammerling, filed 1957, published 1960, https://patents.google.com/patent/US2941556A/en | patent, read 2026-10-16 | adjacent; no descent shown |
| "Tenoning Jigs" | Strother Purdy, *Fine Woodworking* #175, Jan/Feb 2005 | trade publication (synopsis + lead read) | commercial field |
| OSHA 29 CFR 1910.213 | OSHA, https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.213 | regulation, read 2026-10-16 | (a)(15) suitable jigs; (r)(4) point-of-operation guarding; covered workplaces |
| OSHA table-saw eTool | OSHA, https://www.osha.gov/etools/machine-guarding/saws/table | regulatory guidance, not read (per the reviewer) | general table-saw contact and binding hazards |
| Smithsonian NMAH collections search | Smithsonian | museum search (Run 631) | no relevant record located |
| Fine Woodworking forum, "store bought tenoning jig" | Dean ("dstevick"), BarryO, 2006 | forum | offcut concern; stop-block fix |
| Sawmill Creek, "Very Best Tenoning Jig?" | Prashun Patel, Jim Becker, 2010 | forum | build vs. buy |
| Sawmill Creek, "Opinions - Table Saw Tenoning Jigs" | Dave Cav, Peter Quinn, 2011 | forum | rocking jig; adjustment quality |
| Sawmill Creek, "Tenoning Jig - Buy or Make?" | Dave Aronson, Frank Drew, Steve Griffin, Bill White, Mike Wilkins, Mike Monroe, 2010/2011 | forum | alternatives; shop-built reports |
| Sawmill Creek, "question about table saw standardization and tenoning jig" | Zach England, J. Greg Jones, 2009 | forum | compatibility failure example |
| LumberJocks / WoodworkingTalk tenoning-jig threads | — | forum, fetch failed (Run 631) | not represented |

## The reviewer's corrections (17)

- `BLOCKER` — 1. — Exact claim: “a vertical workpiece-holding carriage that rides a table saw’s rip fence (not the miter slot)” and “Rides the rip fence … distinguishing it structurally from the miter-slot-riding sled family.”
- `BLOCKER` — 2. — Exact claim: the central danger is that “the first cheek cutoff [is] trapped between the saw blade and jig” on the second pass, with the stated mitigation “never stand directly in front of the blade line.”
- `BLOCKER` — 3. — Exact claim: “Pairs with: a sharp, flat-ground rip blade and a sacrificial auxiliary fence (BarryO’s named fix) for the fence-contact trap.”
- `BLOCKER` — 4. — Exact claim: Correct Use is limited to a practitioner’s two-pass batching method, registration fit, and a pre-purchase compatibility check.
- `BLOCKER` — 5. — Exact claim: “Access: moderate … the two-pass cheek-cutting method is learnable,” with the pinch-point lesson as the main beginner qualifier.
- `BLOCKER` — 6. — Exact claim: a shop-built fence saddle “cost ‘nothing’” and is reported to “work,” while buy-versus-build is framed mainly as time and adjustment preference.
- `SHOULD-FIX` — 7. — Exact claim: compatibility is mainly “miter-slot spacing,” illustrated as “5.5″/4.25″ vs. 7″.”
- `SHOULD-FIX` — 8. — Exact claim: the jig cuts “box-joint or finger-joint cheeks” on some variants.
- `SHOULD-FIX` — 9. — Exact claim: the jig pairs with “a sharp, flat-ground rip blade.”
- `SHOULD-FIX` — 10. — Exact claim: “First well-documented commercial product: the Delta No. 1172/34-172,” with “decades-long manufacture” inferred from a reconstructed instruction sheet.
- `SHOULD-FIX` — 11. — Exact claim: “No patent found for the classic vertical rip-fence-riding carriage form itself — a checked absence, not a search shortfall.”
- `SHOULD-FIX` — 12. — Exact claim: “No museum or collection record exists for this tool at the Smithsonian NMAH — checked and confirmed absent.”
- `SHOULD-FIX` — 13. — Exact claim: “The bandsaw can substitute directly,” and loose/floating tenons can make the jig “moot.”
- `SHOULD-FIX` — 14. — Exact claim: Dean’s batch rule—cut every front cheek, reset, then every back cheek—is presented as correct-use discipline.
- `SHOULD-FIX` — 15. — Exact claim: the entry’s safety section centers a single forum account while the relevant OSHA text is dismissed as “not tenoning-jig-specific.”
- `SHOULD-FIX` — 16. — Exact claim: confidence is MEDIUM because the tool has broad practitioner coverage and a manufacturer instruction-sheet source.
- `MINOR` — 17. — Exact claim: the entry opens and closes with extensive run timing, queue state, research passes orchestration, model discrepancy, ticket, image-process, and corpus-reconnaissance notes.
